SCR Basics: How a Silicon Controlled Rectifier Switches AC Power

Author: Abloom Instruction Date: November 18, 2026

A diode conducts whenever its anode is positive. An SCR — a silicon controlled rectifier — is a diode with a gate: it blocks forward voltage until you pulse the gate, then it conducts and stays conducting even after the gate pulse ends. That latching action is what makes it the workhorse of lamp dimmers, motor speed controls, and battery chargers. This article works out a half-wave controlled rectifier with real 2N5064 numbers.

Schematic of a half-wave controlled rectifier with a 2N5064 SCR feeding a 100 ohm load from a 12 volt RMS transformer, with a 4.7 kilo-ohm gate resistor, beside a plot of the load voltage over one half-cycle showing nothing until the gate fires at 60 degrees and an average of 4.05 volts

Figure 1: A half-wave controlled rectifier (a) — the 2N5064 SCR feeds a 100 Ω load from a 12 V transformer, with a 4.7 kΩ gate resistor. The load sees nothing until the gate fires at 60° (b); the average over the half-cycle is 4.05 V. (Schematic, not to scale.)

How an SCR latches on — and how it turns off

Inside, an SCR is four semiconductor layers (PNPN) instead of a diode's two. With no gate current it blocks voltage in both directions, like two diodes back to back. A short pulse of gate current injects charge that starts regenerative feedback between the inner junctions, and the device snaps on — after that the gate loses all control, and the SCR stays on even if the gate pulse ends. It turns off only when the anode current falls below the holding current, IH = 5 mA maximum for the 2N5064. In an AC circuit that happens by itself at every zero crossing, so the SCR conducts for part of each half-cycle and blocks for the rest. The firing angle α is the delay from the zero crossing to the gate pulse, and it sets how much power reaches the load: a small α means almost the whole half-cycle, a large α means only a sliver.

Worked example — controlling a 12 V supply down to 4.05 V

Feed a 100 Ω load from a 12 V RMS transformer secondary through the SCR, and fire the gate at α = 60°. The peak of the transformer voltage is:

Vm = 12 × √2 = 16.97 V

The average (DC) voltage over a full cycle for a half-wave controlled rectifier is:

Vdc = (Vm / 2Ï€) × (1 + cos α) = (16.97 / 6.283) × (1 + 0.5) = 2.70 × 1.5 = 4.05 V

So the load current averages:

Idc = 4.05 / 100 = 40.5 mA

The RMS load voltage is 7.61 V, so the load takes 7.61² / 100 = 0.58 W. At 50 Hz one half-cycle lasts 10 ms, so a 60° firing angle means the gate pulse arrives 10 × 60 / 180 = 3.33 ms after the zero crossing, and the SCR conducts for the remaining 180° − 60° = 120°. The table shows how the firing angle controls the output:

α = 0°: Vdc = 5.40 V, Idc = 54.0 mA, P = 0.72 W  |  α = 60°: Vdc = 4.05 V, Idc = 40.5 mA, P = 0.58 W  |  α = 90°: Vdc = 2.70 V, Idc = 27.0 mA, P = 0.36 W

The peak load current is much larger than the average, because the current only flows in short pulses: at the top of the sine wave the load sees almost the full peak, minus the SCR's on-state drop of about 1 V:

Ipeak = (16.97 − 1) / 100 ≈ 160 mA

Sizing the gate resistor

The 2N5064 is a sensitive-gate SCR: its datasheet gives a gate trigger current IGT of 200 µA maximum and a gate trigger voltage VGT of 0.8 V maximum. To trigger it reliably, drive the gate with about 1 mA — five times the worst-case trigger current. From a 5 V pulse the resistor is:

RG = (5 − 0.8) / 1 mA = 4.2 kΩ → use 4.7 kΩ

With 4.7 kΩ the gate current is (5 − 0.8) / 4700 = 0.89 mA, still 4.5 times the 200 µA maximum trigger current, and the resistor only dissipates about 3.75 mW. A 1 kΩ resistor from gate to cathode is often added as well — it bleeds away leakage and noise so the SCR cannot false-trigger on a hot day. The gate trigger current rises when the device is cold (350 µA maximum at −40 °C), so a design that works on the bench in summer can fail in winter if the gate drive is marginal.

Checking the ratings

Before trusting the circuit, check the SCR against its datasheet. The reverse voltage it must block is the full peak, 16.97 V, against a 200 V rating — ten times margin. The average current is 40.5 mA against a 0.5 A rating, and the RMS current is 7.61 / 100 = 76 mA against 0.8 A. The SCR itself dissipates roughly its 1 V on-state drop times the average current, about 40 mW — barely warm. The only number that needs respect is the switch-on surge: if the transformer is connected with a large capacitor across the load, the first pulse can be many amps, against a 10 A non-repetitive surge rating.

Safety note: this example works on the 12 V secondary of a transformer, which is safe to touch. A mains-side SCR circuit is a different matter — the gate drive must be isolated with an optocoupler or a pulse transformer, and the circuit must never be touched while powered. A TRIAC, the SCR's bidirectional cousin, does the same job on both half-cycles and is what real lamp dimmers use.

Key points to remember

  • An SCR blocks until its gate is pulsed, then latches on; it turns off only when the anode current falls below the holding current (IH = 5 mA maximum for the 2N5064), which happens at every AC zero crossing.
  • Worked example: 12 V RMS (Vm = 16.97 V), 100 Ω load, α = 60° → Vdc = (Vm / 2Ï€)(1 + cos 60°) = 4.05 V, Idc = 40.5 mA, Vrms = 7.61 V, P = 0.58 W; conduction angle 120°, gate pulse 3.33 ms after the zero crossing at 50 Hz.
  • Firing angle controls the output: α = 0° gives 5.40 V / 0.72 W, α = 60° gives 4.05 V / 0.58 W, α = 90° gives 2.70 V / 0.36 W; peak load current is about 160 mA.
  • Gate design: 2N5064 needs at most 200 µA and 0.8 V to trigger; a 4.7 kΩ resistor from a 5 V pulse gives 0.89 mA, 4.5× margin, at 3.75 mW.
  • Rating check: PIV 17 V vs 200 V, average current 40.5 mA vs 0.5 A, RMS current 76 mA vs 0.8 A, SCR dissipation about 40 mW. Mains-side SCR circuits need isolated gate drive.