A regulator can fail shorted. When it does, the full unregulated supply voltage lands on your circuit — a 12 V rail can jump to 20 V in a millisecond, and every capacitor, IC and LED on it dies. A crowbar is the last line of defence: it watches the rail, and the moment the voltage climbs too high it deliberately short-circuits the rail, blowing the fuse and cutting power before the load is damaged. It sacrifices a 20-cent fuse to save the whole board. This article designs one for a 12 V, 1 A load and works out every number.
Figure 1: A crowbar on a 12 V rail (a) — the Zener watches the voltage and fires the SCR gate when it rises too high. The rail trips at 13.6 V, clamps to 1.4 V, and the fuse blows (b). (Schematic, not to scale.)
How it works — the formulas
Three parts do the job. The Zener diode sets the trip point: it stays off while the rail is normal, and breaks down when the rail rises above its Zener voltage plus the SCR's gate trigger voltage. The SCR is the switch: once its gate is triggered it latches on and stays on, shorting the rail to ground through a fraction of an ohm. The fuse is the part that actually disconnects the power: the short-circuit current blows it, and the rail falls to zero. R1 holds the gate at 0 V against leakage and noise so the SCR cannot trigger by accident, and R2 limits the current through the Zener and the gate:
Vtrip = Vz + VGT
Igate = (Vfault − Vz − VGT) / R2
The SCR is the right switch for this job because it latches: unlike a transistor, it stays on after the gate signal is gone, so the short stays in place until the fuse clears. But that latching is also why the fuse is essential — the crowbar alone cannot turn the power off, it can only short the rail and wait for the fuse to blow.
Worked example — protecting a 12 V, 1 A load
Take the circuit in Figure 1: a 12 V rail, a load drawing up to 1 A, a 2 A fast-blow fuse F1, a 13 V Zener (1N4743A, 1 W, ±5%), R2 = 100 Ω, R1 = 1 kΩ, and a BT151 SCR. The BT151's datasheet ratings are VDRM 500 V, IT(AV) 7.5 A, IT(RMS) 12 A, ITSM 100 A for 10 ms, I²t 50 A²s, gate trigger current 2 mA typical / 15 mA maximum, gate trigger voltage 0.6 V typical / 1.5 V maximum, on-state voltage 1.4 V typical, and holding current 7 mA typical / 20 mA maximum.
The trip point is Vtrip = 13 + 0.6 = 13.6 V typically — 13% above the 12 V nominal. Because the Zener is ±5%, the real trip point sits between 12.35 + 0.6 = 12.95 V and 13.65 + 0.6 = 14.25 V. Check the margin: a 12 V supply regulated to ±5% tops out at 12.6 V, which is 0.35 V below the lowest possible trip point — tight, but it works. If that margin feels too small, use a 15 V Zener instead and accept a 15.6 V trip.
Now the fault. Suppose the regulator fails and the supply jumps to 20 V. The Zener breaks down and the gate current is Igate = (20 − 13 − 0.6) / 100 Ω = 64 mA (R1 takes only 0.6 V / 1 kΩ = 0.6 mA of it, so the gate gets about 63 mA). That is more than four times the BT151's 15 mA maximum trigger current, so the SCR fires instantly — its turn-on time is about 2 µs. The Zener dissipates 13 V × 64 mA = 0.83 W and R2 dissipates 64 mA² × 100 Ω = 0.41 W, but only for those microseconds until the SCR fires, so the 1 W Zener and a 1 W R2 are comfortable.
With the SCR on, the rail collapses to the SCR's on-state voltage, about 1.4 V — the load is safe. The fault current is limited by the supply; say it can deliver 10 A. The 2 A fast-blow fuse sees five times its rating and clears in tens of milliseconds. The fuse's I²t at 10 A for 20 ms is 10² × 0.02 = 2 A²s, against the SCR's 50 A²s rating — a 25× margin, so the SCR easily survives the wait. The SCR dissipates 10 A × 1.4 V = 14 W for 10 ms, just 0.14 J of energy. Once the fuse blows the rail falls to 0 V, the current stops, and the SCR turns off. Replace the fuse and fix the regulator before powering up again.
The catch — the crowbar latches, so the fuse must do the work
An SCR stays on as long as the current through it is above its holding current — 20 mA maximum for the BT151. The load alone draws 1 A, so even after the fault current stops, the load current keeps the SCR latched. The crowbar cannot reset itself: without the fuse, the rail would sit shorted at 1.4 V forever, the supply would cook, and the SCR would eventually fail. Size the fuse so that it blows fast at the fault current but never at the normal load: here 2 A for a 1 A load is the right balance. And never test a crowbar by shorting the rail by hand — it is designed to short the supply, and the fuse and the wiring must be able to carry the fault current until the fuse clears.
Designing a 5 V crowbar
Suppose you need to protect a 5 V logic rail. Use a 5.6 V Zener (1N4734A): the trip point is 5.6 + 0.6 = 6.2 V, 24% above nominal — the usual trip level for a 5 V rail. With R2 = 47 Ω, a fault that pushes the supply to 9 V gives a gate current of (9 − 5.6 − 0.6) / 47 Ω = 59.6 mA, again far above the 15 mA trigger maximum. A 1 A fast-blow fuse suits a 0.5 A logic load. The same BT151 works — its 500 V blocking voltage is far more than a 5 V rail needs, but its 2 mA typical trigger current is what matters, and that is the same at any rail voltage.
Crowbar or TVS diode?
A TVS diode is the other common overvoltage protector, and it works differently: it clamps the rail at its breakdown voltage and absorbs the fault energy itself, without a fuse and without latching. That makes it simpler and self-resetting, but it can only absorb a limited amount of energy — a sustained fault will overheat and destroy it. A crowbar handles a much bigger fault, because the fuse takes the energy, but it sacrifices the fuse and needs a manual reset. Use a TVS for short spikes and ESD, and a crowbar where a failed regulator could hold the rail high for seconds.
Key points to remember
- The trip point is Vtrip = Vz + VGT: a 13 V Zener plus a 0.6 V gate trigger gives 13.6 V typically (12.95–14.25 V with the Zener's ±5% tolerance) on a 12 V rail.
- Worked example: at a 20 V fault, the gate current is (20 − 13 − 0.6) / 100 Ω = 64 mA — more than 4× the BT151's 15 mA maximum trigger current, so the SCR fires in about 2 µs.
- With the SCR on, the rail clamps to about 1.4 V; the 2 A fast-blow fuse clears the ~10 A fault in tens of milliseconds, and the fuse I²t of 2 A²s is 25× inside the SCR's 50 A²s rating.
- The SCR latches: the 1 A load current is far above its 20 mA holding current, so the crowbar cannot reset itself — the fuse must blow, and you must replace it and fix the fault before powering up.
- Design rule: for a 5 V rail use a 5.6 V Zener (trip 6.2 V) with R2 = 47 Ω and a 1 A fuse; use a TVS diode for short spikes and a crowbar for a sustained regulator failure.